Download Mv Switchgear & Controlgear Drawing PDF

TitleMv Switchgear & Controlgear Drawing
File Size761.6 KB
Total Pages68
Document Text Contents
Page 1

Page

Page

Medium Voltage
Ed.

Original

02122010-007

007
LKP +

Date

Date

Replaced by

Title page/cover sheet

1

Modification

0 76

Appr

Replacement of

8 93

71

2

4

2010-11-08

1

2

=

Name

5

/

EPLAN Software & Service
GmbH & Co. KG

Project description Medium Voltage

+49 (0) 2173 3964 0

Number of pages

Commission

D-40789

Edit date

02122010-007

Created on

Power Engineering

Job number

71

ENERGY_F26_001

LKP

An der alten Ziegelei 2

Manufacturer (company)

Project name Power Engineering MV

Phone.

Company / customer

2010-12-02 by (short name)

007

Monheim am Rhein

EPLAN Software & Service
GmbH & Co. KG

Page 2

Page

Page

Medium Voltage
Ed.

1

Original

02122010-007

007
EPLAN +

Date

Date

Replaced by

Table of contents

1

Modification

0 76

Appr

Replacement of

8 93

71

2.a

4

2010-07-05

2

2

=

Name

5

/

Edited by

Column X: An automatically generated page was edited

supplementary page field

Table of contents
DatePage description

ENERGY_F06_001

XPage

&EAA/1 EPLANTitel- / Deckblatt 05.07.2010

&EAB/2 EPLANTable of contents 05.07.2010

&EAB/2.a EPLANTable of contents 05.07.2010

&EAB/2.b EPLANTable of contents 05.07.2010

&EEB/3 EPLANIEC 61355 01.06.2010

&EMS/5 EPLANBill of materials 09.06.2010

&EMZ/6 EPLANFunctional connection diagramm 09.06.2010

&EAC/7 EPLANStructure identifier overview 09.06.2010

=S01&ELU/1 EPLANFront View (total) 02.06.2010

=S01&ELU/2 EPLANFront View (total) 01.06.2010

=S01&ELU/3 EPLANFoundation frame 02.06.2010

=S01&EFA/4 EPLANTotal Overview Single Line Scheme 08.06.2010

=S01&EFS/5 EPLANInterconnection Terminal -XI1 01.06.2010

=S01&EFS/6 EPLANInterconnection Terminal -XI2 01.06.2010

=S01&EFS/7 EPLANInterconnection Terminal -XI2 01.06.2010

=S01&EFS/8 EPLANInterconnection Terminal -XI2 01.06.2010

=S01&EFS/9 EPLANInterconnection Terminal -XI3 01.06.2010

=S01&EFS/10 EPLANInterconnection Terminal -XI4 01.06.2010

=S01&EFS/11 EPLANInterconnection Terminal -XI4 01.06.2010

=S01&EFS/12 EPLANInterconnection Terminal -XI4 01.06.2010

=S01&EFS/13 EPLANInterconnection Terminal -XI5 01.06.2010

=S01+C01&EFA/1 EPLANSingle line 30.05.2010

=S01+C01&EFS/5 EPLANAux. voltage supply 30.05.2010

=S01+C01&EFS/6 EPLANMV Part 30.05.2010

=S01+C01&EFS/7 EPLANMV Part 30.05.2010

=S01+C01&EFS/8 EPLANVoltage transformer bus 30.05.2010

=S01+C01&EFS/9 EPLANProtection relays overview 30.05.2010

=S01+C01&EFS/10 EPLANBinary inputs 30.05.2010

=S01+C01&EFS/11 EPLANBinary inputs 30.05.2010

=S01+C01&EFS/12 EPLANClosing Circuit 30.05.2010

=S01+C01&EFS/13 EPLANTriping Circuit 30.05.2010

=S01+C01&EFS/14 EPLANInterlocking 30.05.2010

=S01+C01&EFS/15 EPLANInterlocking 30.05.2010

Page 34

Page

Page

Medium Voltage
Ed.

16

Original

02122010-007

007
EPLAN +

Date

Date

Replaced by

S01

C01
Alarm Signals

1

Modification

0 76

Appr

Replacement of

8 93

71

18

4

2010-05-30

17

2

=

Name

5

/

EARTH FAULT
ALARM

CONDITION
MONITORING

ALARM

COMMON
PRE-ALARM

COMNTROL
MCB TRIP

MOTOR
CHARGER
MCB TRIP

HEATERS
& LIGHT
MCB TRIP

ARC RELAY
IRF

VAMP RELAY
IRF

OVERCURRENT
ALARM

224223

27-XI2 28

37-XI2

3029-XI2

222221-XX

4039-XI2

38

3635-XI2

26

3433-XI2

3231-XI2

25-XI2

225 226 227 228 229 230 231 232 233 234

201-XX 202 203 204

95

96 98

-FB10
/5.1 95

96 98

-FB11
/5.3 95

96 98

-FB12
/5.5

205 214213212211210209208207206

8 9

10

-F18
/9.3

X3

IRF

16 17

18

/9.8

X2

IF

13 14

15

/9.8

X2

A2

10 11

12

/9.8

X2

A3

5

6

/9.8

X2

A5

7

8

/9.8

X2

A4

-BR1

-54/

-53/

-24L+/ -4L+ / 16.0

-63 /

-64 /

-55/ -65 /

-57/ -67 /

-56/ -66 /

-52/

-61 /-51/

-62 /

Page 35

Page

Page

Medium Voltage
Ed.

17

Original

02122010-007

007
EPLAN +

Date

Date

Replaced by

S01

C01
CB Contacts

1

Modification

0 76

Appr

Replacement of

8 93

71

19

4

2010-05-30

18

2

=

Name

5

/

SPARE
CB CLOSED

SPARE
CB OPEN

SPARE
CB OPEN

SPARE
CB OPEN

SPARE
CB CLOSED

SPARE
CB CLOSED

SPARE
CB CLOSED

SPARE
CB TRUCK
IN SERVICE

SPARE
CB TRUCK
IN TEST

SPARE
CB TRUCK
IN TEST

SPARE
CB SPRING
CHARGED

B15

B16

14

13

-S3

/21.5

-XB-QB1 B2

B3

31

-S4 32
/21.5

B11

B12

14

13

-S5
/21.6

B7

B8

44

43

-S5
/21.6

A15

B1

54

53

-S5
/21.6

B9

B10

31

-S5 32
/21.6

B13

B14

21

-S5 22
/21.7

D9

D10

/21.7
-S8 34

2

9

33

-X

-X

D11

D12

13

14

/21.7
34

33

-S9

-X

-X

D7

D8

17

18

/21.7
54

53

-S9

-X

-X

A16

A9

-S1 54

53

/21.4

121-XC 123 125 127 129 131 133 135 137 139 141

122-XC 124 126 128 130 132 134 136 138 140 142

Page 67

Page

Page

Medium Voltage
Ed.

12.a

Original

02122010-007

007
LKP +

Date

Date

Replaced by

S03Terminal diagram -X3

1

Modification

0 76

Appr

Replacement of

8 93

71

14

4

2010-12-02

13

2

=

Name

5

/

Terminal diagram ENERGY_F13_001Terminaltypes

T-No.

Übersetzung fehlt

Terminal with closed
disconnecting slider

INTERNAL

Terminal with opened
disconnecting slider

EXTERNAL

9 8

Strip

7 6 5 4 31 2 3 4 5 6 7 8 9 10

4

3

2

1

C
o
n
n
e
ctio

n
p
o
in
t

Designation
(Target)

Function text

10

9

8

7

6

5

4

3

2

1

6

5

Interconnection / Jumper
CLOSED

Interconnection / Jumper
OPENED

Ju
m
p
e
rs

10

Ju
m
p
e
rs 11

8

7

9

11 1011 2

T-No

Control jackInterlock

11

Page / column1

C
o
n
n
e
ctio

n
p
o
in
t

Designation
(Source)

=S03+-X3 5x2,5mm² mm²-WT1L1
5x2,5mm² mm²-WT1L2

5x2,5mm² mm²-WT1L3

-T1L12S3 /1.4801 L1/

-T1L12S1 /1.4805 L1/

-T1L22S3 /1.6806 L2/

-T1L22S1 /1.6810 L2/

-T1L32S3 /1.7811 L3/

/1.8815

-T1L32S2 /1.7816 L3/

/1.8817

-T1L12S2 /1.4818 L1/

-T1L22S2 /1.6819 L2/

-T1L32S1 /1.8820 L3/

/1.5PE

/1.6PE

/1.8PE

Page 68

Page

Page

Medium Voltage
Ed.

13

Original

02122010-007

007
LKP +

Date

Date

Replaced by

S03Terminal diagram -X4

1

Modification

0 76

Appr

Replacement of

8 93

71

4

2010-12-02

14

2

=

Name

5

/

Terminal diagram ENERGY_F13_003

9 8

Strip

7 6 5 4 31 2 3 4 5 6 7 8 9 10 11 11 10 2

11

10

9

8

7

6

5

4

3

2

1

11

Page / column1

C
o
n
n
e
ctio

n
p
o
in
t

Designation
(Source)

C
o
n
n
e
ctio

n
p
o
in
t

Designation
(Target)

Function text

10

9

8

7

6

5

4

3

2

1

EXTERNAL INTERNAL

Disconnecting slider closed

Disconnecting slider opened

Terminal number

Page reference

Page reference

Terminal number

Drawing legend

Interconnection jumper OPENED

Interconnection jumper CLOSED

locked

Service jack

=S03+-X4 5x2,5mm² mm²-WT1L11

2,5mm² mm²

5x2,5mm² mm²-WT1L22

5x2,5mm² mm²-WT1L33

2,5mm² mm²

801
-T1

/2.1
S2 L1/2S3

805
817 -T1

/2.1
-X4 S1 L1/2S1grgr

818
-T1

/2.1
S3 L1/2S2

PE
-X4

/2.1
-PE 805

806
-T2

/2.2
S2 L2/2S3

810
805 -T2

/2.2
-X4 S1 L2/2S1grgr

819
-T2

/2.3
S3 L2/2S2

PE
-X4

/2.3
-PE 810

811
-T2

/2.4
S2 L3/2S3

816
817 -T2

/2.4
-X4 S1 L3/2S1gr

820
-T2

/2.4
S3 L3/2S2

PE
-X4

/2.4
-PE 816

815
810 -X4

/2.5
-X4 817 grgr

817
816 -X4

/2.5
-X4 815 grgrgr

900

/2.6

Similer Documents